Na Zhijie's new excellent 6 SUV report, the threshold will be lowered

A few days ago, we obtained a set of Nazhijie's new excellent 6 SUV declaration from the network. The new car has been adjusted in terms of appearance and interior. The power will be added with a 1.6T turbocharged engine from PSA. The current model is equipped with 1.8T and 2.0T engines, and the new 1.6T new 6 SUV prices will be lower. In the early news, Na Zhijie's new excellent 6 SUV is expected to be officially released in the first half of 2017.

After reading the following points, this article is half finished:

1, the new excellent 6 SUV has been adjusted in appearance and interior design, especially the interior has been refitted with the popular large-size vertical LCD screen;

2. Power will add 1.6T turbocharged engine from PSA Group. The price threshold of new car is expected to decrease compared with cash.

Na Zhijie's new excellent 6 SUV report, the threshold will be lowered

In terms of appearance, from the exposure report, the new excellent 6 SUV has been adjusted in appearance details. Compared to the current model, the air intake grille and fog light area of ​​the new model has a new design. In addition, the LED daytime running lights inside the headlights have added a light-guided design that looks more refined. In the rear part, the new excellent 6 SUV mainly adjusts the design of the rear bumper, and the layering is more distinct.

Na Zhijie's new excellent 6 SUV report, the threshold will be lowered

Na Zhijie's new excellent 6 SUV report, the threshold will be lowered

Na Zhijie's new excellent 6 SUV report, the threshold will be lowered

The interior part, from the spy photos previously exposed, the biggest highlight of the new excellent 6 SUV interior is equipped with a large vertical LCD screen. In addition, the multimedia control area including the LCD screen and the air conditioning panel have also been redesigned.

Na Zhijie's new excellent 6 SUV report, the threshold will be lowered

In the powertrain segment, Nazhijie's new Premium 6 SUV will add a 1.6T turbocharged engine from the PSA Group. This engine is the same as the Dongfeng Citroen C3-XR, with a maximum power of 123kW (167Ps).

Editor's comment: Although the domestic SUV market has maintained rapid growth in the past few years, the market performance of the Nazhijie 6 SUV, which is highly anticipated, is not satisfactory. The upcoming new Optimus 6 SUV attempts to improve overall competitiveness through styling changes, configuration upgrades and new powertrains, and attempts to change the current market dilemma.

Surge Protection Device SPD

Product Description


SPD Surge Protective Device,Lightning Surge Protector
Surge Protection Device (SPD)


It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.

Surge protective Device Model Selection

With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <<Building lightning protection design norm>> GB50057-94(2002 vision)(hereafter brief as <<lightning protection norm>>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.
SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.
As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across." That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage.

SPD for Power Supply System Series Selection Guide

The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.
SPD for power supply system specification selection principle
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.
TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc≥1.15Uo
IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series

Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5ºC~+40ºC
Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)

Classification

-As per Nominal Discharge Current:
5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage:
275V,320V,385V,420V,440V,460V
- As per to poles
1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
a. With remote signal output ( remote alarm function)
b. Without remote signal output

Selection Principle

- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;

Product Features

1, built-in over-current overheating, temperature control circuit technology.

2, the module design, easy installation, online replacement.

3, low leakage current, fast response time, low residual voltage.

4, alarm indication device, green (normal) v red (fault).

Model/Technical Parameters WR-B60 WR-B80 WR-B100 WR-B120 WR-B150
Rated Operating Voltage Un (V ~) 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V
Maximum Continuous Operating Voltage Uc (V ~) kV 385V 420V 385V 420V 385V 420V 385V 420V 385V 420V
Voltage Protection Level Up (V ~) kV ≤1.8≤2.2 ≤2.4≤2.5 ≤2.5≤3.2 ≤3.4≤3.7 ≤4.0≤4.5

Maximum Discharge

Current Imax(8/μ20μs)kA

60 80 100 120 150

Nominal Discharge

Current In(8/μ20μs)kA

30 40 60 80 100
Response Time <25 <100
L/N(mm²)The Cross Section Of L/N Line 16,25 16,25 16,25 16,25 25,35
PE (mm²)The Cross Section Of PE Line 16,25 25,35 25,35 25,35 35
Fuse or Switch (A) 63A 63A 63A,100A 63A,100A 63A,125A
The Line Section of Communication and Alarm (mm²) ≥ 1.5

Operating

Environment-C

(-40ºC~-+85ºC)
Relative humidity 25 ºC ≤95%
installation Standard Rail35mm
Material of Outer Covering Fiber Glass Reinforced Plastic

Surge Protector SPD,Surge Protection Device SPD,SPD

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.zjthermalrelay.com