Application of DL-X Thermometer on High Frequency Welding Machine

DL-X high frequency machine special thermometer
At present, most high-frequency machines do not have suitable supporting infrared thermometers. They are judged only by the experience of the master worker. This is obviously a big defect of the high-frequency machine, and it has great limitations. It has strict temperature requirements. The products, which rely on experience alone, are completely out of order. An infrared temperature measurement instrument suitable for high-frequency machines is also required.
DL-X infrared thermometer features: laser sighting, ultra-small target can be measured 2mm (special requirements up to 1mm), long-distance non-contact measurement of temperature, to prevent the influence of mid-frequency, high-frequency magnetic field, fast 5ms response speed, its own The liquid crystal display temperature of the LCD can be used to control the temperature of the heated workpiece in conjunction with the thermostat.
DL-X infrared thermometer parameters
DL-X series of high-precision small target infrared thermometer with accurate laser sighting function, LCD display the current state, you can easily align the target and indicate the best measurement distance. Provide users with convenient, high reliability measurement methods.
Laser indication measurement
Spot indicates the best measurement position and can measure a small target of 2.5
Durable sensor head meets IP65 (NEMA4) standard
LCD temperature display, on-site emissivity adjustment
4-20mA and digital simultaneous output optional
Main application areas
High-frequency induction heating, high-frequency welding, forging, heat treatment, metallurgy, kilns, plate glass, refractories, heating furnaces.
model
temperature range
Distance coefficient
Measurement wavelength
DL-X1
-25~800°C
75:1
8~14 um
DL-X2
300~1400°C
150:1
1.6 um
DL-X3
600~2000°C
200:1
1 um
Measurement parameters
Temperature range -25-800°C 300-1400°C 600-2000°C (expandable)
Measurement wavelength 8-14um 1.6um 1um
Distance coefficient 75:1 150:1 200:1
System Accuracy ±0.5% or ±2°C (Large Value) (Ring Temperature: 23±5°C)
Repetitive Accuracy ±0.5% or ±1°C (Large Value) (Ring Temperature: 23±5°C)
Temperature resolution 0.5°C
Response time <5ms (95%)
Emissivity 0.100-1.099 steps 0.001
High-frequency machine supporting infrared thermometer application:
High-frequency machine external infrared temperature measurement, through the infrared temperature control workpiece heating temperature, reach the set temperature, infrared temperature measurement has a lower limit alarm function, prompting the operator has finished heating the workpiece. This precise temperature control improves the process accuracy of the heated workpiece and ensures the quality of the final product.