Professional Supplier of Aerial Bundled Cable (ABC) 3X35sqmm

Model NO.: AAC+AAC
Rated Voltage: 0.6/1 Kv, 11kv, 33kv
Cores: Duplex, Triplex, Quadruplex
Type of Phase Conductor: AAC
Type of Neutral Conductor: AAC, AAAC, ACSR
Trademark: Jinshui
Specification: ISO, CE, CCC
Origin: Zhengzhou Henan
Model NO.: AAC+AAC
Rated Voltage: 0.6/1 Kv, 11kv, 33kv
Cores: Duplex, Triplex, Quadruplex
Type of Phase Conductor: AAC
Type of Neutral Conductor: AAC, AAAC, ACSR
Trademark: Jinshui
Specification: ISO, CE, CCC
Origin: Zhengzhou Henan

Specifications

Standard: National Standard IEC and ASTM

Rated Voltage: 0.6/1KV, 11KV, 33KV

Construction: Phase conductor: aluminum stranded(AAC)

                         Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)

                         Insulation: XLPE or PE

Application:  The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.

Uesd for overhead service application such as street linghting, outdoor lighting and temporary service for cunstruction.which improves the safety and reliance of electrified wire netting.

 

1 Type:Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop

 

    a Duplex Service Drop

   Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

 

   b Triplex Service Drop

   Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

 

    c Quadruplex Service Drop

    Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

 

 

2  Construction
     a Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

 

    b  Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded

 

    c Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)

Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75°C temperature rating is available upon request.
 


Professional Supplier of Aerial Bundled Cable (ABC) 3X35sqmm
Professional Supplier of Aerial Bundled Cable (ABC) 3X35sqmm
Professional Supplier of Aerial Bundled Cable (ABC) 3X35sqmm

 

Specifications

Standard: National Standard IEC and ASTM

Rated Voltage: 0.6/1KV, 11KV, 33KV

Construction: Phase conductor: aluminum stranded(AAC)

                         Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)

                         Insulation: XLPE or PE

Application:  The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.

Uesd for overhead service application such as street linghting, outdoor lighting and temporary service for cunstruction.which improves the safety and reliance of electrified wire netting.

 

1 Type:Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop

 

    a Duplex Service Drop

   Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

 

   b Triplex Service Drop

   Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

 

    c Quadruplex Service Drop

    Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

 

 

2  Construction
     a Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

 

    b  Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded

 

    c Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)

Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75°C temperature rating is available upon request.
 


Professional Supplier of Aerial Bundled Cable (ABC) 3X35sqmm
Professional Supplier of Aerial Bundled Cable (ABC) 3X35sqmm
Professional Supplier of Aerial Bundled Cable (ABC) 3X35sqmm

 

Flexible Busbar

Flexible Busbar,Flexible Busbar Manufacturers,Flexible Busbar Current Rating,Flexible Busbar Connections

Flexible Busbar,Bended Rigid Busbar Co., Ltd. , http://www.nbrigidbusbar.com